Hermetically Sealed Military Relays and Contactors
A military relay is a hermetically sealed electromagnetic switch qualified to a DLA performance specification: MIL-PRF-39016 for established reliability relays up to 5 amperes, MIL-PRF-83536 up to 25 amperes, and MIL-PRF-6106 for 25 amperes and up, which covers contactors. NASA programs add screening from EEE-INST-002 Section R1.
Updated
Relay types and where each one is used
Pick the specification from the contact current first, then the package and whether the relay must hold its position with no coil power. The three general specifications split the current range, and each one covers latching and nonlatching designs through its slash sheets.
| Type | Governing document | Contact range | Typical use |
|---|---|---|---|
| Signal and low level relays (TO-5 cans, crystal cans) | MIL-PRF-39016 | Low level up to 5 A ac or dc | Avionics, flight computers, telemetry switching, test sets |
| General power relays | MIL-PRF-83536 | Low level up to 25 A ac or dc | Load switching in aircraft, missile, spacecraft, ship and ground support equipment |
| Contactors and high current relays | MIL-PRF-6106 | 25 A resistive and up | Bus switching, power distribution, heaters and motors |
| Latching relays | Slash sheets under all three | Varies by sheet | Circuits that must hold state through power loss or save coil power |
| Hybrid relays | MIL-PRF-28776 | Per sheet | Established reliability hybrid relays with semiconductor output stages |
MIL-PRF-6106 defines a relay contactor as a relay whose main contacts are designed to switch high amperage power, considered to be 25 amperes or more, typically to distribute power from the source to the load bus or between buses. Contactors often carry auxiliary contacts for low current switching, which the same specification describes as 5 amperes or less, driven by the same actuator. When a relay goes into a harness or a power distribution box, see our wire harness sourcing page for how the assembly side is handled.
The specifications that govern military relays
The general specification sets construction, test and quality requirements, and each slash sheet defines one relay family. Revisions below are the latest we read on EverySpec in October 2026; confirm the current revision on ASSIST before you release a drawing.
| Document | What it covers | Status we read |
|---|---|---|
| MIL-PRF-39016G (25 Aug 2014) | Hermetically sealed, established reliability electromagnetic relays from low level to 5 A, for electronic and communication equipment | Active; supersedes MIL-PRF-39016F w/Amendment 1 |
| MIL-PRF-83536D (2 Jan 2013) | Hermetically sealed, established reliability relays from low level to 25 A, for aircraft, missile, spacecraft, ship and ground support equipment | Active; supersedes MIL-PRF-83536C |
| MIL-PRF-6106P w/Amendment 1 (22 May 2017) | Electromechanical relays rated 25 A resistive and up, Types I to IV by duty and sealing | Active; class O relay standards inactive for new design |
| MIL-PRF-28776E (10 Sep 2012) | Hybrid relays, established reliability | Listed on EverySpec; confirm the current revision on ASSIST |
| GSFC S-311-P-754 | NASA Goddard relay specification for Level 1 use, low level to 25 A | Named in EEE-INST-002; obtain the current issue from the project |
| EEE-INST-002 Section R1 (May 2003) | NASA screening and qualification tables for electromagnetic relays | Invoked by many NASA contracts; check your parts plan |
MIL-PRF-6106P classifies relays by type: Type I is continuous duty, hermetically sealed; Type II is continuous duty, unsealed; Type III is intermittent duty in hermetic, environmentally sealed or unsealed forms; Type IV is continuous duty, environmentally sealed but not hermetic. The same document notes that class O relays from the old MIL-R-6106B no longer meet the specification and that existing class O standards are kept only for government replenishment spares.
Have a part like this?Send it in under a minute. A person replies within 1 business day.How the part number is built: M39016/10-001L
An established reliability relay part number has four fields, and the last letter is the failure rate level. MIL-PRF-39016G gives this exact example, and MIL-PRF-83536D uses the same layout with M83536 in front.
| Field | Example | Meaning |
|---|---|---|
| Military designator | M | Military part |
| Specification sheet | 39016/10 | Slash sheet 10 of MIL-PRF-39016, which fixes the package, contact form and ratings |
| Dash number | -001 | Specific coil voltage, terminal and option combination on that sheet |
| Failure rate level | L | Established reliability level from table I of the specification |
Table I defines the levels in percent failures per 10,000 cycles:
| Letter | Failure rate, percent per 10,000 cycles |
|---|---|
| L | 3.0 |
| M | 1.0 |
| P | 0.1 |
| R | 0.01 |
The levels are established at 90 percent confidence for qualification and 60 percent for maintaining qualification, based on 100,000 cycles at +125 °C under rated load. The specification notes the rate assumes an average of 10 cycles per hour for 1,000 hours under MIL-STD-690. With acquiring activity approval, a relay qualified to a better level may be substituted for a worse one, for example P for M, but relays shall not be remarked unless the contract allows it. Qualified relays are marked with a JAN or J brand above or below the M.
MIL-PRF-6106 relays carry no failure rate letter. Its PIN is M6106, the sheet number and a dash number, for example M6106/20-001, and relays still covered by MS or AN standards keep the PIN format of those standards.
Contact ratings and the load you actually switch
A relay rating is only valid for the load type it was tested with, so match resistive, inductive, motor and lamp loads separately. MIL-PRF-39016 and MIL-PRF-83536 define three contact load ranges:
- Low level: 10 microamperes at 50 millivolts to 10 milliamperes at 6 volts.
- Intermediate: 10 milliamperes at 6 volts to 100 milliamperes at 28 volts.
- High level: above 100 milliamperes at 28 volts.
The 25 ampere ratings in MIL-PRF-83536 apply to resistive loads only; motor, inductive and lamp ratings on those sheets are lower. MIL-PRF-6106 adds application cautions a designer should read before choosing a part:
- Capacitive loads. The inrush into a capacitor can weld contacts. The specification recommends analyzing circuit impedance and choosing a relay whose motor load rating is greater than 18 percent of the peak switching current. It also warns that low break current on capacitive dc loads builds up contact material that can lock contacts closed, shortening life.
- 115/200 volt ratings. These mean a three phase system. The relay may not interrupt 200 volts across a single set of contacts; ask the manufacturer before using it that way.
- Transfer contacts. Do not use them to transfer loads between phases or between unsynchronized ac sources.
- Coil voltage. All three specifications carry the caution that any coil voltage below rated will compromise operation. MIL-PRF-39016 adds that pickup, hold and dropout voltages are test values, not design criteria.
Latching relays, construction and mounting styles
A latching relay holds its last position with the coil off, and its main hazard is the magnetically neutral state. The specifications require two coil latching relays to be designed so that energizing both coils at once does not leave the contacts in neutral, and they screen for it. In service, MIL-PRF-39016 and MIL-PRF-6106 say the latch and reset coils should not be pulsed together, should not be pulsed below rated voltage, and the pulse width should be at least three times the specified operate time.
Construction requirements explain why these parts last and why counterfeits fail:
- Hermetic seal. Relays are dried, degassed, backfilled and sealed by welding. MIL-PRF-39016 sets a standard leak rate of 1 x 10-6 atm cm3/s of air per MIL-STD-883 Method 1014.
- Prohibited finishes. MIL-PRF-39016 prohibits pure tin, zinc plating and cadmium plating inside and outside the relay, because of whisker growth, and prohibits silicone compounds for any purpose.
- Plug-in pins. Gold plating for plug-in terminals is called out to ASTM B488 over a nickel underplate.
- Dissimilar metals. Contact couples are limited to those permitted by MIL-STD-889.
Mounting and termination are set by the slash sheet. MIL-PRF-39016 describes mounting brackets that must be an integral part of the relay, solder pin wire leads, and plug-in pin terminals that mate with a socket. The manufacturer may hot solder dip terminals or shorten leads as optional value added services when the purchase order says so. If you need a bracket, header plate or enclosure machined to carry a relay, that can ride on the same order; see CNC machining.
Space grade screening: EEE-INST-002 Section R1
For NASA Level 1 and Level 2 work, a military relay is acceptable only with added process controls. EEE-INST-002 Table 1 says MIL-PRF-39016, MIL-PRF-6106 and MIL-PRF-83536 relays are acceptable for Levels 1 and 2 if they are procured to failure rate M or better where applicable, the lot was subjected to small particle cleaning and internal inspection during assembly, and the lot passes particle impact noise detection (PIND) afterwards. For Level 2, three random samples may instead pass destructive physical analysis (DPA) per GSFC S-311-M-70, without residual gas analysis.
Table 2 of the same section lists the screening flow for relays bought outside those specifications, including:
- Cleaning and small particle inspection to the manufacturer's approved procedure, Levels 1 and 2.
- PIND at all three levels.
- Internal moisture detection: insulation resistance of at least 10,000 megohms before and after energizing the coil at 140 percent of rated voltage for 2.5 minutes.
- High temperature soak and low, high and room temperature run-in with low level contact loads, 2,500 cycles per run-in for Level 1.
- Radiographic inspection per MSFC-STD-355C for Level 1.
- Fine leak at 1.0 x 10-8 cc/s and gross leak testing, Levels 1 and 2.
- A percent defective allowable of 5 percent for Level 1 and 15 percent for Level 2.
EEE-INST-002 treats relays rated up to and including 2 amperes dc resistive as low level and anything higher as high level. It also prohibits pure tin as a final finish or undercoat and calls for header glass inspection at 10x or more. For how relay grades fit the wider parts program, see EEE parts grades.
What to put on the purchase order
- Full PIN exactly as drawn, including slash sheet, dash number and failure rate letter, for example M39016/10-001L.
- General specification and slash sheet with revision, or a statement that the revision in the contract applies.
- Qualified source: a manufacturer listed in DLA's Qualified Products Database for that sheet, bought from the manufacturer or its authorized distributor.
- Whether failure rate substitution is allowed, and that parts shall not be remarked.
- Lot or date code traceability on the certificate of conformance and the package label, with a single date code if your program requires it.
- NASA level and any added screening, PIND, DPA or lot data, with the data delivered.
- Optional services you want, such as hot solder dip or lead trimming, stated explicitly.
- Packaging that protects leads and headers; ESD packaging when the relay has internal diodes that are not part of the coil circuit, which MIL-PRF-39016 says may be ESD sensitive.
- DFARS counterfeit clauses and any prime flow-downs that apply.
Our certificate of conformance page explains what the cert should state.
Counterfeit and quality risks, and how to receive relays
The common relay problems are remarked failure rate letters, wrong dash numbers with the same footprint, old date codes sold as new, and opened or reworked cans. Military relays are also a long tail item: many slash sheets have few qualified makers, so legacy programs end up buying from brokers. DFARS 252.246-7008 defines electronic parts as integrated circuits, discrete electronic components and circuit assemblies; a relay is not named, so whether your contract treats it as covered is a question for your contracts team, though many buyers apply the authorized source rule anyway. Our counterfeit parts avoidance guide covers the clauses and AS6081 brokers.
At receiving:
- Read the marking character by character against the PO, including the JAN or J brand, failure rate letter and date code.
- Check the circuit diagram on the can against the slash sheet; the specification requires it as a terminal view.
- Inspect header glass and terminals under magnification for cracks, chips and solder rework. EEE-INST-002 lists blisters, foreign material, dark spots, cracks and chips as irregularities to look for.
- Look for evidence of a reopened can, such as a disturbed weld seam or adjunct sealant where the drawing does not allow it.
- Match lot and date code on the part, bag and certificate, and hold parts whose paperwork does not tie to the lot.
See receiving inspection for the dock routine and certs and traceability for the paperwork chain.
How we source relays and contactors
We do not stock relays, publish prices or act as an authorized or franchised distributor for any manufacturer. We source the PIN on your drawing through the manufacturer or its authorized and franchised distributors, flow your failure rate, screening and data requirements down in writing, and check the certificates against the PO before shipment.
- Relays bought alone or kitted with sockets, brackets and harness parts per assembly.
- Relays combined with harness builds, machined brackets or ground support equipment on one purchase order.
- Inactive slash sheets and out of production relays chased under counterfeit-avoidance controls; see obsolete aerospace parts.
Related electromechanical parts: circuit breakers and switches, motors and actuators, sensors and transducers, or the electromechanical overview. For the connectors that usually sit next to them, see circular connectors.
Request relays or a relay kit
Send the full PINs, quantities, NASA level or screening flow, and whether failure rate substitution is acceptable through the harness and electromechanical quote form. Those details decide which qualified sources can supply the part under your contract. A person replies within one business day, and every order ships with a certificate of conformance. For defense and launch programs with controlled drawings, read how we handle files and controlled programs first.
Send the job. A person replies within 1 business day.
Part, quantity and date are enough to start. Drawings and the mutual NDA follow by reply, and controlled programs never send technical data through this site.
We have it.
Reference . A person replies within 1 business day. Watch for our email from [email protected].
Questions
What does the letter at the end of an M39016 relay part number mean?
It is the failure rate level. MIL-PRF-39016G Table I defines L as 3.0 percent per 10,000 cycles, M as 1.0, P as 0.1 and R as 0.01. The levels are established at 90 percent confidence for qualification and 60 percent for maintaining it, based on 100,000 cycles at +125 C under rated load. MIL-PRF-83536 uses the same letters and values.
Can I use a P level relay where the drawing calls for M?
Usually, with approval. MIL-PRF-39016G says that with acquiring activity approval, relays qualified to a lower, better failure rate may be substituted for higher failure rate parts, and gives P for M as the example. The same paragraph says relays shall not be remarked unless the contract or order allows it, so the part ships with its own P marking.
What is the difference between MIL-PRF-83536 and MIL-PRF-6106?
Current range and failure rate. MIL-PRF-83536 covers hermetically sealed, established reliability relays from low level up to 25 amperes, with failure rate letters in the part number. MIL-PRF-6106 covers relays rated 25 amperes resistive and up, including contactors, with types for continuous or intermittent duty and hermetic, environmentally sealed or unsealed enclosures. Its part numbers carry no failure rate letter.
Are military relays acceptable for NASA Level 1 hardware?
Only with added controls. EEE-INST-002 Section R1 accepts MIL-PRF-39016, MIL-PRF-6106 and MIL-PRF-83536 relays for Levels 1 and 2 when they are procured to failure rate M or better where applicable, the lot had small particle cleaning and internal inspection during assembly, and the lot passes PIND testing afterwards. GSFC S-311-P-754 is the Goddard relay specification written for Level 1 use.
Why do latching relays sometimes fail to switch?
A common cause is the magnetically neutral position. MIL-PRF-39016 and MIL-PRF-6106 warn that latch and reset coils should not be pulsed at the same time or below rated voltage, and that the pulse width should be at least three times the specified operate time. If those conditions are not met the relay can rest in neutral, with normally open and normally closed contacts both open.
Can a 25 amp relay switch a 25 amp motor?
Not necessarily. MIL-PRF-83536D states that 25 ampere ratings apply to resistive loads only and that motor, inductive and lamp ratings are less than 25 amperes. Read the slash sheet for each load type. For capacitive loads, MIL-PRF-6106 recommends a relay whose motor load rating exceeds 18 percent of the peak switching current to avoid welded contacts.
Related
Sources
- MIL-PRF-39016G, Relays, Electromagnetic, Established Reliability (25 Aug 2014), EverySpec
- MIL-PRF-83536D, Relays, Electromagnetic, Established Reliability, 25 Amperes and Below (2 Jan 2013), EverySpec
- MIL-PRF-6106P w/Amendment 1, Relays, Electromagnetic (22 May 2017), EverySpec
- EverySpec FSC 5945 index, Relays and Solenoids (MIL-PRF-28776E listing)
- NASA/TP-2003-212242, EEE-INST-002, Section R1 Relays, Electromagnetic (May 2003)
- Acquisition.gov, DFARS 252.246-7008 Sources of Electronic Parts